T85.630A ICD-10-CM Code: Leakage of cranial or spinal infusion catheter, initial encounter
Billing Status: YES. This is a valid, specific, and billable ICD-10-CM reference.
Inpatient Payment Groups (MS-DRG)
MS-DRGs this diagnosis helps define, as principal or secondary, per the CMS ICD-10-CM/PCS MS-DRG Definitions Manual v43.0, Appendix B.
- MS-DRG 091 — OTHER DISORDERS OF NERVOUS SYSTEM WITH MCC (MDC 01)
- MS-DRG 092 — OTHER DISORDERS OF NERVOUS SYSTEM WITH CC (MDC 01)
- MS-DRG 093 — OTHER DISORDERS OF NERVOUS SYSTEM WITHOUT CC/MCC (MDC 01)
A diagnosis appearing in a group's logic does not by itself determine the DRG assigned to a stay; the grouper uses the full claim.
Official Registry Overview & Definition
Official Tabular Instructional Notes
Sequencing, inclusion, and exclusion notes published for T85.630A in the official ICD-10-CM tabular list.
Inclusion Terms
Alternative terms the tabular list files under this code.
- Leakage of epidural infusion catheter
- Leakage of intrathecal infusion catheter infusion catheter
- Leakage of subdural infusion catheter
- Leakage of subarachnoid infusion catheter
Excludes2 — Not Included Here
Conditions not covered by this code, but which may be reported alongside it when both are present.
- failure and rejection of transplanted organs and tissue (T86.-) Compare T85.630A vs T86 →
- any encounters with medical care for postprocedural conditions in which no complications are present, such as:
- artificial opening status (Z93.-) Compare T85.630A vs Z93 →
- closure of external stoma (Z43.-) Compare T85.630A vs Z43 →
- fitting and adjustment of external prosthetic device (Z44.-) Compare T85.630A vs Z44 →
- burns and corrosions from local applications and irradiation (T20-T32) Compare T85.630A vs T20 →
- complications of surgical procedures during pregnancy, childbirth and the puerperium (O00-O9A) Compare T85.630A vs O00 →
- mechanical complication of respirator ventilator
- poisoning and toxic effects of drugs and chemicals (T36-T65 with fifth or sixth character 1-4 or 6) Compare T85.630A vs T36 →
- postprocedural fever (R50.82) Compare T85.630A vs R50.82 →
- specified complications classified elsewhere, such as:
- cerebrospinal fluid leak from spinal puncture (G97.0) Compare T85.630A vs G97.0 →
- colostomy malfunction (K94.0-) Compare T85.630A vs K94.0 →
- disorders of fluid and electrolyte imbalance (E86-E87) Compare T85.630A vs E86 →
- functional disturbances following cardiac surgery (I97.0-I97.1) Compare T85.630A vs I97.0 →
- intraoperative and postprocedural complications of specified body systems (D78.-, E36.-, E89.-, G97.3-, G97.4, H59.3-, H59.-, H95.2-, H95.3, I97.4-, I97.5, J95.6-, J95.7, K91.6-, L76.-, M96.-, N99.-) Compare T85.630A vs D78 →
- ostomy complications (J95.0-, K94.-, N99.5-) Compare T85.630A vs J95.0 →
- postgastric surgery syndromes (K91.1) Compare T85.630A vs K91.1 →
- postlaminectomy syndrome NEC (M96.1) Compare T85.630A vs M96.1 →
- postmastectomy lymphedema syndrome (I97.2) Compare T85.630A vs I97.2 →
- postsurgical blind-loop syndrome (K91.2) Compare T85.630A vs K91.2 →
- ventilator associated pneumonia (J95.851) Compare T85.630A vs J95.851 →
Use Additional Code
Supplementary codes the tabular list directs you to add.
- Use additional code for adverse effect, if applicable, to identify drug (T36-T50 with fifth or sixth character 5)
- Use additional code(s) to identify the specified condition resulting from the complication
- Use additional code to identify devices involved and details of circumstances (Y62-Y82)
Change history
- FY2017 — 2016-10-01Description revisedLeakage of epidural and subdural infusion catheter, initial encounter → Leakage of cranial or spinal infusion catheter, initial encounterFY2017 changes
- FY2017 — 2016-10-01Short description revisedLeakage of epidural and subdural infusion catheter, init → Leakage of cranial or spinal infusion catheter, initFY2017 changes
Verify Before Coding
- Billable — reportable as written.
- CC as a secondary diagnosis (FY2026). Can raise the stay's MS-DRG severity tier.
From the code registry, the Medicare Code Editor, and the MS-DRG Definitions Manual. Check it against a full claim.
Contextual Map
Every relationship of T85.630A in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
Hierarchy
- S00-T88 — Chapter 19: Injury, Poisoning and Certain Other Consequences of External Causes (S00-T88) (S00-T88) [Hierarchy]
- T80-T88 — Complications of surgical and medical care, not elsewhere classified [Hierarchy]
Clinical classification (CCSR)
- INJ037 — Complication of other surgical or medical care, injury, initial encounter [CCSR]
Potential MS-DRG
- CC — Complication or Comorbidity [MS-DRG severity]: “As a secondary diagnosis this code can raise the stay's MS-DRG severity tier (CC).”
- DRG 091 — OTHER DISORDERS OF NERVOUS SYSTEM WITH MCC [MS-DRG]: “OTHER DISORDERS OF NERVOUS SYSTEM WITH MCC (MDC 01)”
- DRG 092 — OTHER DISORDERS OF NERVOUS SYSTEM WITH CC [MS-DRG]: “OTHER DISORDERS OF NERVOUS SYSTEM WITH CC (MDC 01)”
- DRG 093 — OTHER DISORDERS OF NERVOUS SYSTEM WITHOUT CC/MCC [MS-DRG]: “OTHER DISORDERS OF NERVOUS SYSTEM WITHOUT CC/MCC (MDC 01)”
MDC crossing · procedures (8892)
- MDC 01 — Diseases and Disorders of the Nervous System [MDC crossing]: “Diseases and Disorders of the Nervous System — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”
- 0016070 — Bypass Cerebral Ventricle to Nasopharynx with Autologous Tissue Substitute, Open Approach [Same-MDC procedure]: “Bypass Cerebral Ventricle to Nasopharynx with Autologous Tissue Substitute, Open Approach — grouped in MDC 01, the procedure side of this code's crossing.” · check together
- 0016071 — Bypass Cerebral Ventricle to Mastoid Sinus with Autologous Tissue Substitute, Open Approach [Same-MDC procedure]: “Bypass Cerebral Ventricle to Mastoid Sinus with Autologous Tissue Substitute, Open Approach — grouped in MDC 01, the procedure side of this code's crossing.” · check together
- 0016072 — Bypass Cerebral Ventricle to Atrium with Autologous Tissue Substitute, Open Approach [Same-MDC procedure]: “Bypass Cerebral Ventricle to Atrium with Autologous Tissue Substitute, Open Approach — grouped in MDC 01, the procedure side of this code's crossing.” · check together
- 0016073 — Bypass Cerebral Ventricle to Blood Vessel with Autologous Tissue Substitute, Open Approach [Same-MDC procedure]: “Bypass Cerebral Ventricle to Blood Vessel with Autologous Tissue Substitute, Open Approach — grouped in MDC 01, the procedure side of this code's crossing.” · check together
- 0016074 — Bypass Cerebral Ventricle to Pleural Cavity with Autologous Tissue Substitute, Open Approach [Same-MDC procedure]: “Bypass Cerebral Ventricle to Pleural Cavity with Autologous Tissue Substitute, Open Approach — grouped in MDC 01, the procedure side of this code's crossing.” · check together
- and 8887 more
Index entries
- Complication (s) (from) (of), catheter NEC (device), cranial infusion, mechanical, leakage[Index term]
- Complication (s) (from) (of), catheter NEC (device), epidural infusion, mechanical, leakage[Index term]
- Complication (s) (from) (of), catheter NEC (device), intrathecal infusion, mechanical, leakage[Index term]
- Complication (s) (from) (of), catheter NEC (device), spinal infusion, mechanical, leakage[Index term]
- Complication (s) (from) (of), catheter NEC (device), subarachnoid infusion, mechanical, leakage[Index term]
- Complication (s) (from) (of), catheter NEC (device), subdural infusion, mechanical, leakage[Index term]
- Leak, leakage, device, implant or graft, catheter NEC, infusion NEC, spinal (epidural) (subdural)[Index term]
Nearest codes (40)
- T85 — Complications of other internal prosthetic devices, implants and grafts [Sibling]
- T85.622D — Displacement of permanent sutures, subsequent encounter [Sibling]
- T85.622S — Displacement of permanent sutures, sequela [Sibling]
- T85.623 — Displacement of artificial skin graft and decellularized allodermis [Sibling]
- T85.623A — Displacement of artificial skin graft and decellularized allodermis, initial encounter [Sibling]
- T85.623D — Displacement of artificial skin graft and decellularized allodermis, subsequent encounter [Sibling]
- T85.623S — Displacement of artificial skin graft and decellularized allodermis, sequela [Sibling]
- T85.624 — Displacement of insulin pump [Sibling]
- and 32 more
Change history (2)
- FY2017 — Description revised [Change history]
- and 1 more
Relationships & Classification
Clinical classification (AHRQ CCSR):INJ037 — Complication of other surgical or medical care, injury, initial encounter (default).
Clinical Classifications Software Refined (CCSR) for ICD-10-CM Diagnoses. Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality.
Potential MS-DRG Relationships (FY2026)
CC — Complication or Comorbidity. Reported as a secondary diagnosis, this code raises the stay's MS-DRG severity tier — except when the principal diagnosis is one of 53 clinically related codes on its CMS exclusion list.
Named in the grouper logic of 3 MS-DRGs: DRG 091 (MDC 01), DRG 092 (MDC 01), DRG 093 (MDC 01).
From the CMS MS-DRG Definitions Manual (Appendices B and C). Actual DRG assignment depends on the complete claim.
Frequently Asked Questions (FAQ) & Clinical Guidance
Does T85.630A require a 7th character?
Yes. The appropriate 7th character is to be added to each code from category T85.
Nearest Codes in This Family
Official ICD-10-CM classifications closest to T85.630A in its code family, with their registry titles.
- T85.628A — Displacement of other specified internal prosthetic devices, implants and grafts, initial encounter
- T85.628D — Displacement of other specified internal prosthetic devices, implants and grafts, subsequent encounter
- T85.628S — Displacement of other specified internal prosthetic devices, implants and grafts, sequela
- T85.63 — Leakage of other specified internal prosthetic devices, implants and grafts
- T85.630 — Leakage of cranial or spinal infusion catheter
- T85.630D — Leakage of cranial or spinal infusion catheter, subsequent encounter
- T85.630S — Leakage of cranial or spinal infusion catheter, sequela
- T85.631 — Leakage of intraperitoneal dialysis catheter
- T85.631A — Leakage of intraperitoneal dialysis catheter, initial encounter
- T85.631D — Leakage of intraperitoneal dialysis catheter, subsequent encounter
Indexed Clinical Terms (7)
Clinical term phrases from the official ICD-10-CM Index to Diseases and Injuries that map to this code.
- Complication (s) (from) (of), catheter NEC (device), cranial infusion, mechanical, leakage
- Complication (s) (from) (of), catheter NEC (device), epidural infusion, mechanical, leakage
- Complication (s) (from) (of), catheter NEC (device), intrathecal infusion, mechanical, leakage
- Complication (s) (from) (of), catheter NEC (device), spinal infusion, mechanical, leakage
- Complication (s) (from) (of), catheter NEC (device), subarachnoid infusion, mechanical, leakage
- Complication (s) (from) (of), catheter NEC (device), subdural infusion, mechanical, leakage
- Leak, leakage, device, implant or graft, catheter NEC, infusion NEC, spinal (epidural) (subdural)