Skip to main content
ICD-10-PCS/02H/02HK40Z
Inpatient Procedure Code

02HK40Z

Insertion of Pressure Sensor Monitoring Device into Right Ventricle, Percutaneous Endoscopic Approach

Insert of Pressure Sens into R Ventricle, Perc Endo Approach

Axis Breakdown

Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.

PositionValueMeaning
1
Section0

Medical and Surgical

2
Body System2

Heart and Great Vessels

3
Root OperationH

Insertion

Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part

4
Body PartK

Ventricle, Right

5
Approach4

Percutaneous Endoscopic

6
Device0

Monitoring Device, Pressure Sensor

7
QualifierZ

No Qualifier

Potential MS-DRG Relationships (FY2026)

The MS-DRG grouper treats this as an operating room procedure. It appears in the surgical logic of 3 MS-DRGs:

From the CMS MS-DRG Definitions Manual, Appendix E. Actual DRG assignment depends on the complete claim.

Contextual Map

Every relationship of 02HK40Z in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.

PCS table

  • 02H[PCS table]
  • [object Object] — Section: [object Object] [Section]: “[object Object]”
  • [object Object] — Body System: [object Object] [Body System]: “[object Object]”
  • [object Object] — Operation: [object Object] [Operation]: “[object Object]”

MS-DRG participation

  • DRG 260 — CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH MCC [MS-DRG]: “CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH MCC — Cardiac Pacemaker Revision Except Device Replacement (MDC 05)”
  • DRG 261 — CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH CC [MS-DRG]: “CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH CC — Cardiac Pacemaker Revision Except Device Replacement (MDC 05)”
  • DRG 262 — CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITHOUT CC/MCC [MS-DRG]: “CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITHOUT CC/MCC — Cardiac Pacemaker Revision Except Device Replacement (MDC 05)”

Nearest codes

  • 02H440Z — Insertion of Pressure Sensor Monitoring Device into Coronary Vein, Percutaneous Endoscopic Approach [One axis away]
  • 02H640Z — Insertion of Pressure Sensor Monitoring Device into Right Atrium, Percutaneous Endoscopic Approach [One axis away]
  • 02H740Z — Insertion of Pressure Sensor Monitoring Device into Left Atrium, Percutaneous Endoscopic Approach [One axis away]
  • 02HK00Z — Insertion of Pressure Sensor Monitoring Device into Right Ventricle, Open Approach [One axis away]
  • 02HK30Z — Insertion of Pressure Sensor Monitoring Device into Right Ventricle, Percutaneous Approach [One axis away]
  • 02HK42Z — Insertion of Monitoring Device into Right Ventricle, Percutaneous Endoscopic Approach [One axis away]
  • 02HK43Z — Insertion of Infusion Device into Right Ventricle, Percutaneous Endoscopic Approach [One axis away]
  • 02HK4DZ — Insertion of Intraluminal Device into Right Ventricle, Percutaneous Endoscopic Approach [One axis away]

Change history

No changes recorded for this code — unchanged since the FY2026 (April) baseline of the change ledger.