02WA0MZ
Revision of Cardiac Lead in Heart, Open Approach
Axis Breakdown
Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.
| Position | Value | Meaning |
|---|---|---|
| 1 | Section0 | Medical and Surgical |
| 2 | Body System2 | Heart and Great Vessels |
| 3 | Root OperationW | Revision Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device |
| 4 | Body PartA | Heart |
| 5 | Approach0 | Open |
| 6 | DeviceM | Cardiac Lead |
| 7 | QualifierZ | No Qualifier |
Potential MS-DRG Relationships (FY2026)
The MS-DRG grouper treats this as an operating room procedure. It appears in the surgical logic of 12 MS-DRGs:
- MDC 01 — Peripheral, Cranial Nerve and Other Nervous System Procedures: DRG 040, DRG 041, DRG 042
- MDC 05 — Cardiac Pacemaker Revision Except Device Replacement: DRG 260, DRG 261, DRG 262
- MDC 21 — Other O.R. Procedures for Injuries: DRG 907, DRG 908, DRG 909
- MDC 24 — Other O.R. Procedures for Multiple Significant Trauma: DRG 957, DRG 958, DRG 959
From the CMS MS-DRG Definitions Manual, Appendix E. Actual DRG assignment depends on the complete claim.
Related Codes
Same operation — other Approach
Same table and root operation, differing only in the approach character.
02WA3MZ — Revision of Cardiac Lead in Heart, Percutaneous Approach, 02WA4MZ — Revision of Cardiac Lead in Heart, Percutaneous Endoscopic Approach, 02WAXMZ — Revision of Cardiac Lead in Heart, External Approach
Same operation — other Device
Same table and root operation, differing only in the device character.
02WA0CZ — Revision of Extraluminal Device in Heart, Open Approach, 02WA0DZ — Revision of Intraluminal Device in Heart, Open Approach, 02WA0JZ — Revision of Synthetic Substitute in Heart, Open Approach, 02WA0KZ — Revision of Nonautologous Tissue Substitute in Heart, Open Approach, 02WA0NZ — Revision of Intracardiac Pacemaker in Heart, Open Approach, 02WA0QZ — Revision of Implantable Heart Assist System in Heart, Open Approach, 02WA0RZ — Revision of Short-term External Heart Assist System in Heart, Open Approach, 02WA0YZ — Revision of Other Device in Heart, Open Approach, +4 more
Contextual Map
Every relationship of 02WA0MZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
PCS table
- 02W[PCS table]
- [object Object] — Section: [object Object] [Section]: “[object Object]”
- [object Object] — Body System: [object Object] [Body System]: “[object Object]”
- [object Object] — Operation: [object Object] [Operation]: “[object Object]”
MS-DRG participation (12)
- DRG 040 — PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH MCC [MS-DRG]: “PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH MCC — Peripheral, Cranial Nerve and Other Nervous System Procedures (MDC 01)”
- DRG 041 — PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH CC OR PERIPHERAL NEUROSTIMULATOR [MS-DRG]: “PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH CC OR PERIPHERAL NEUROSTIMULATOR — Peripheral, Cranial Nerve and Other Nervous System Procedures (MDC 01)”
- DRG 042 — PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITHOUT CC/MCC [MS-DRG]: “PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITHOUT CC/MCC — Peripheral, Cranial Nerve and Other Nervous System Procedures (MDC 01)”
- DRG 260 — CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH MCC [MS-DRG]: “CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH MCC — Cardiac Pacemaker Revision Except Device Replacement (MDC 05)”
- DRG 261 — CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH CC [MS-DRG]: “CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITH CC — Cardiac Pacemaker Revision Except Device Replacement (MDC 05)”
- DRG 262 — CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITHOUT CC/MCC [MS-DRG]: “CARDIAC PACEMAKER REVISION EXCEPT DEVICE REPLACEMENT WITHOUT CC/MCC — Cardiac Pacemaker Revision Except Device Replacement (MDC 05)”
- DRG 907 — OTHER O.R. PROCEDURES FOR INJURIES WITH MCC [MS-DRG]: “OTHER O.R. PROCEDURES FOR INJURIES WITH MCC — Other O.R. Procedures for Injuries (MDC 21)”
- DRG 908 — OTHER O.R. PROCEDURES FOR INJURIES WITH CC [MS-DRG]: “OTHER O.R. PROCEDURES FOR INJURIES WITH CC — Other O.R. Procedures for Injuries (MDC 21)”
- and 4 more
MDC crossing · diagnoses (10874)
- MDC 01 — Diseases and Disorders of the Nervous System [MDC crossing]: “Diseases and Disorders of the Nervous System — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”
- MDC 05 — Diseases and Disorders of the Circulatory System [MDC crossing]: “Diseases and Disorders of the Circulatory System — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”
- A02.21 — Salmonella meningitis [Same-MDC diagnosis]: “Salmonella meningitis — grouped in MDC 01, the diagnosis side of this code's crossing.” · check together
- A06.6 — Amebic brain abscess [Same-MDC diagnosis]: “Amebic brain abscess — grouped in MDC 01, the diagnosis side of this code's crossing.” · check together
- A17.0 — Tuberculous meningitis [Same-MDC diagnosis]: “Tuberculous meningitis — grouped in MDC 01, the diagnosis side of this code's crossing.” · check together
- A17.1 — Meningeal tuberculoma [Same-MDC diagnosis]: “Meningeal tuberculoma — grouped in MDC 01, the diagnosis side of this code's crossing.” · check together
- A17.81 — Tuberculoma of brain and spinal cord [Same-MDC diagnosis]: “Tuberculoma of brain and spinal cord — grouped in MDC 01, the diagnosis side of this code's crossing.” · check together
- and 10869 more
Nearest codes
- 02WA02Z — Revision of Monitoring Device in Heart, Open Approach [One axis away]
- 02WA03Z — Revision of Infusion Device in Heart, Open Approach [One axis away]
- 02WA07Z — Revision of Autologous Tissue Substitute in Heart, Open Approach [One axis away]
- 02WA08Z — Revision of Zooplastic Tissue in Heart, Open Approach [One axis away]
- 02WA0CZ — Revision of Extraluminal Device in Heart, Open Approach [One axis away]
- 02WA0DZ — Revision of Intraluminal Device in Heart, Open Approach [One axis away]
- 02WA0JZ — Revision of Synthetic Substitute in Heart, Open Approach [One axis away]
- 02WA0KZ — Revision of Nonautologous Tissue Substitute in Heart, Open Approach [One axis away]
Change history
No changes recorded for this code — unchanged since the FY2026 (April) baseline of the change ledger.