02WY3KZ ICD-10-PCS Code: Revision of Nonautologous Tissue Substitute in Great Vessel, Percutaneous Approach
Revision of Nonaut Sub in Great Vessel, Perc Approach
Axis Breakdown
Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.
| Position | Value | Meaning |
|---|---|---|
| 1 | Section0 | Medical and Surgical |
| 2 | Body System2 | Heart and Great Vessels |
| 3 | Root OperationW | Revision Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device |
| 4 | Body PartY | Great Vessel |
| 5 | Approach3 | Percutaneous |
| 6 | DeviceK | Nonautologous Tissue Substitute |
| 7 | QualifierZ | No Qualifier |
MS-DRG Grouper Relationships (FY2026)
Potential MS-DRG participation — not a DRG assignment.
The MS-DRG grouper treats this as an operating room procedure. It appears in the surgical logic of 3 MS-DRGs:
From the CMS MS-DRG Definitions Manual, Appendix E. Actual DRG assignment depends on the complete claim.
Related Codes
Same operation — other Body Part
Same table and root operation, differing only in the body part character.
02WA3KZ — Revision of Nonautologous Tissue Substitute in Heart, Percutaneous Approach, 02WF3KZ — Revision of Nonautologous Tissue Substitute in Aortic Valve, Percutaneous Approach, 02WG3KZ — Revision of Nonautologous Tissue Substitute in Mitral Valve, Percutaneous Approach, 02WH3KZ — Revision of Nonautologous Tissue Substitute in Pulmonary Valve, Percutaneous Approach, 02WJ3KZ — Revision of Nonautologous Tissue Substitute in Tricuspid Valve, Percutaneous Approach
Same operation — other Approach
Same table and root operation, differing only in the approach character.
02WY0KZ — Revision of Nonautologous Tissue Substitute in Great Vessel, Open Approach, 02WY4KZ — Revision of Nonautologous Tissue Substitute in Great Vessel, Percutaneous Endoscopic Approach, 02WYXKZ — Revision of Nonautologous Tissue Substitute in Great Vessel, External Approach
Same operation — other Device
Same table and root operation, differing only in the device character.
02WY32Z — Revision of Monitoring Device in Great Vessel, Percutaneous Approach, 02WY33Z — Revision of Infusion Device in Great Vessel, Percutaneous Approach, 02WY37Z — Revision of Autologous Tissue Substitute in Great Vessel, Percutaneous Approach, 02WY38Z — Revision of Zooplastic Tissue in Great Vessel, Percutaneous Approach, 02WY3CZ — Revision of Extraluminal Device in Great Vessel, Percutaneous Approach, 02WY3DZ — Revision of Intraluminal Device in Great Vessel, Percutaneous Approach, 02WY3JZ — Revision of Synthetic Substitute in Great Vessel, Percutaneous Approach, 02WY3YZ — Revision of Other Device in Great Vessel, Percutaneous Approach
Same procedure category (CCSR), other tables
AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Cardiovascular device procedures, NEC (Cardiovascular Procedures); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.
02PY43Z — Removal of Infusion Device from Great Vessel, Percutaneous Endoscopic Approach, 02PY47Z — Removal of Autologous Tissue Substitute from Great Vessel, Percutaneous Endoscopic Approach, 02PY48Z — Removal of Zooplastic Tissue from Great Vessel, Percutaneous Endoscopic Approach, 02PY4CZ — Removal of Extraluminal Device from Great Vessel, Percutaneous Endoscopic Approach, 02PY4DZ — Removal of Intraluminal Device from Great Vessel, Percutaneous Endoscopic Approach, 02PY4JZ — Removal of Synthetic Substitute from Great Vessel, Percutaneous Endoscopic Approach, 02PY4KZ — Removal of Nonautologous Tissue Substitute from Great Vessel, Percutaneous Endoscopic Approach, 02PY4YZ — Removal of Other Device from Great Vessel, Percutaneous Endoscopic Approach, 02PYX3Z — Removal of Infusion Device from Great Vessel, External Approach, 02PYXDZ — Removal of Intraluminal Device from Great Vessel, External Approach, 03H00DZ — Insertion of Intraluminal Device into Right Internal Mammary Artery, Open Approach, 03H03DZ — Insertion of Intraluminal Device into Right Internal Mammary Artery, Percutaneous Approach, 03H04DZ — Insertion of Intraluminal Device into Right Internal Mammary Artery, Percutaneous Endoscopic Approach, 03H10DZ — Insertion of Intraluminal Device into Left Internal Mammary Artery, Open Approach, 03H13DZ — Insertion of Intraluminal Device into Left Internal Mammary Artery, Percutaneous Approach, 03H14DZ — Insertion of Intraluminal Device into Left Internal Mammary Artery, Percutaneous Endoscopic Approach, 03H20DZ — Insertion of Intraluminal Device into Innominate Artery, Open Approach, 03H23DZ — Insertion of Intraluminal Device into Innominate Artery, Percutaneous Approach, 03H24DZ — Insertion of Intraluminal Device into Innominate Artery, Percutaneous Endoscopic Approach, 03H30DZ — Insertion of Intraluminal Device into Right Subclavian Artery, Open Approach, +530 more
Contextual Map
Every relationship of 02WY3KZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
Run 02WY3KZ with these 5 related codes in Claim Check
PCS table
- 02W[PCS table]— CMS ICD-10-PCS tables
- Medical and Surgical — Section: Medical and Surgical[Section]: “Medical and Surgical”— CMS ICD-10-PCS tables
- Heart and Great Vessels — Body System: Heart and Great Vessels[Body System]: “Heart and Great Vessels”— CMS ICD-10-PCS tables
- Revision — Operation: Revision[Operation]: “Revision”— CMS ICD-10-PCS tables
MS-DRG participation
- DRG 270 — OTHER MAJOR CARDIOVASCULAR PROCEDURES WITH MCC[MS-DRG]: “OTHER MAJOR CARDIOVASCULAR PROCEDURES WITH MCC — Other Major Cardiovascular Procedures (MDC 05)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 271 — OTHER MAJOR CARDIOVASCULAR PROCEDURES WITH CC[MS-DRG]: “OTHER MAJOR CARDIOVASCULAR PROCEDURES WITH CC — Other Major Cardiovascular Procedures (MDC 05)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 272 — OTHER MAJOR CARDIOVASCULAR PROCEDURES WITHOUT CC/MCC[MS-DRG]: “OTHER MAJOR CARDIOVASCULAR PROCEDURES WITHOUT CC/MCC — Other Major Cardiovascular Procedures (MDC 05)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
Clinical classification (CCSR)
- CAR029 — Cardiovascular device procedures, NEC[CCSR category]: “Cardiovascular device procedures, NEC — Cardiovascular Procedures”— AHRQ CCSR for ICD-10-PCS Procedures (HCUP) · v2026.1
MDC crossing · diagnoses (1844)
- MDC 05 — Diseases and Disorders of the Circulatory System[MDC crossing]: “Diseases and Disorders of the Circulatory System — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”— CMS MS-DRG Definitions Manual · FY2026
- A36.81 — Diphtheritic cardiomyopathy[Same-MDC diagnosis]: “Diphtheritic cardiomyopathy — grouped in MDC 05, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A39.50 — Meningococcal carditis, unspecified[Same-MDC diagnosis]: “Meningococcal carditis, unspecified — grouped in MDC 05, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A39.51 — Meningococcal endocarditis[Same-MDC diagnosis]: “Meningococcal endocarditis — grouped in MDC 05, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A39.52 — Meningococcal myocarditis[Same-MDC diagnosis]: “Meningococcal myocarditis — grouped in MDC 05, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A39.53 — Meningococcal pericarditis[Same-MDC diagnosis]: “Meningococcal pericarditis — grouped in MDC 05, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- and 1839 more
Nearest codes
- 02WA3KZ — Revision of Nonautologous Tissue Substitute in Heart, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 02WF3KZ — Revision of Nonautologous Tissue Substitute in Aortic Valve, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 02WG3KZ — Revision of Nonautologous Tissue Substitute in Mitral Valve, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 02WH3KZ — Revision of Nonautologous Tissue Substitute in Pulmonary Valve, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 02WJ3KZ — Revision of Nonautologous Tissue Substitute in Tricuspid Valve, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 02WY0KZ — Revision of Nonautologous Tissue Substitute in Great Vessel, Open Approach[One axis away]— CMS ICD-10-PCS tables
- 02WY32Z — Revision of Monitoring Device in Great Vessel, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 02WY33Z — Revision of Infusion Device in Great Vessel, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
Change history
No changes recorded for this code. This ledger tracks additions, deletions and description changes from FY2026 (April) onward. Note changes are not tracked.
Read from: CMS ICD-10-PCS code tables, index and definitions — FY2026 (April); CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v43; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels