05HY0YZ ICD-10-PCS Code: Insertion of Other Device into Upper Vein, Open Approach
Axis Breakdown
Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.
| Position | Value | Meaning |
|---|---|---|
| 1 | Section0 | Medical and Surgical |
| 2 | Body System5 | Upper Veins |
| 3 | Root OperationH | Insertion Putting in a nonbiological appliance that monitors, assists, performs, or prevents a physiological function but does not physically take the place of a body part |
| 4 | Body PartY | Upper Vein |
| 5 | Approach0 | Open |
| 6 | DeviceY | Other Device |
| 7 | QualifierZ | No Qualifier |
MS-DRG Grouper Relationships (FY2026)
Potential MS-DRG participation — not a DRG assignment.
The MS-DRG grouper treats this as an operating room procedure. It appears in the surgical logic of 18 MS-DRGs:
- MDC 01 — Peripheral, Cranial Nerve and Other Nervous System Procedures: DRG 040, DRG 041, DRG 042
- MDC 03 — Other Ear, Nose, Mouth and Throat O.R. Procedures: DRG 143, DRG 144, DRG 145
- MDC 05 — Other Vascular Procedures: DRG 252, DRG 253, DRG 254
- MDC 10 — Other Endocrine, Nutritional and Metabolic O.R. Procedures: DRG 628, DRG 629, DRG 630
- MDC 21 — Other O.R. Procedures for Injuries: DRG 907, DRG 908, DRG 909
- MDC 24 — Other O.R. Procedures for Multiple Significant Trauma: DRG 957, DRG 958, DRG 959
From the CMS MS-DRG Definitions Manual, Appendix E. Actual DRG assignment depends on the complete claim.
Related Codes
Same operation — other Approach
Same table and root operation, differing only in the approach character.
05HY3YZ — Insertion of Other Device into Upper Vein, Percutaneous Approach, 05HY4YZ — Insertion of Other Device into Upper Vein, Percutaneous Endoscopic Approach
Same operation — other Device
Same table and root operation, differing only in the device character.
05HY02Z — Insertion of Monitoring Device into Upper Vein, Open Approach, 05HY03Z — Insertion of Infusion Device into Upper Vein, Open Approach, 05HY0DZ — Insertion of Intraluminal Device into Upper Vein, Open Approach
Same procedure category (CCSR), other tables
AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Cardiovascular device procedures, NEC (Cardiovascular Procedures); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.
04WY4CZ — Revision of Extraluminal Device in Lower Artery, Percutaneous Endoscopic Approach, 04WY4DZ — Revision of Intraluminal Device in Lower Artery, Percutaneous Endoscopic Approach, 04WY4JZ — Revision of Synthetic Substitute in Lower Artery, Percutaneous Endoscopic Approach, 04WY4KZ — Revision of Nonautologous Tissue Substitute in Lower Artery, Percutaneous Endoscopic Approach, 04WY4YZ — Revision of Other Device in Lower Artery, Percutaneous Endoscopic Approach, 04WYX7Z — Revision of Autologous Tissue Substitute in Lower Artery, External Approach, 04WYXCZ — Revision of Extraluminal Device in Lower Artery, External Approach, 04WYXDZ — Revision of Intraluminal Device in Lower Artery, External Approach, 04WYXJZ — Revision of Synthetic Substitute in Lower Artery, External Approach, 04WYXKZ — Revision of Nonautologous Tissue Substitute in Lower Artery, External Approach, 05P00MZ — Removal of Neurostimulator Lead from Azygos Vein, Open Approach, 05P03MZ — Removal of Neurostimulator Lead from Azygos Vein, Percutaneous Approach, 05P04MZ — Removal of Neurostimulator Lead from Azygos Vein, Percutaneous Endoscopic Approach, 05P0XMZ — Removal of Neurostimulator Lead from Azygos Vein, External Approach, 05P30MZ — Removal of Neurostimulator Lead from Right Innominate Vein, Open Approach, 05P33MZ — Removal of Neurostimulator Lead from Right Innominate Vein, Percutaneous Approach, 05P34MZ — Removal of Neurostimulator Lead from Right Innominate Vein, Percutaneous Endoscopic Approach, 05P3XMZ — Removal of Neurostimulator Lead from Right Innominate Vein, External Approach, 05P40MZ — Removal of Neurostimulator Lead from Left Innominate Vein, Open Approach, 05P43MZ — Removal of Neurostimulator Lead from Left Innominate Vein, Percutaneous Approach, +576 more
Contextual Map
Every relationship of 05HY0YZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
Run 05HY0YZ with these 5 related codes in Claim Check
PCS table
- 05H[PCS table]— CMS ICD-10-PCS tables
- Medical and Surgical — Section: Medical and Surgical[Section]: “Medical and Surgical”— CMS ICD-10-PCS tables
- Upper Veins — Body System: Upper Veins[Body System]: “Upper Veins”— CMS ICD-10-PCS tables
- Insertion — Operation: Insertion[Operation]: “Insertion”— CMS ICD-10-PCS tables
MS-DRG participation (18)
- DRG 040 — PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH MCC[MS-DRG]: “PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH MCC — Peripheral, Cranial Nerve and Other Nervous System Procedures (MDC 01)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 041 — PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH CC OR PERIPHERAL NEUROSTIMULATOR[MS-DRG]: “PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITH CC OR PERIPHERAL NEUROSTIMULATOR — Peripheral, Cranial Nerve and Other Nervous System Procedures (MDC 01)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 042 — PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITHOUT CC/MCC[MS-DRG]: “PERIPHERAL, CRANIAL NERVE AND OTHER NERVOUS SYSTEM PROCEDURES WITHOUT CC/MCC — Peripheral, Cranial Nerve and Other Nervous System Procedures (MDC 01)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 143 — OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITH MCC[MS-DRG]: “OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITH MCC — Other Ear, Nose, Mouth and Throat O.R. Procedures (MDC 03)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 144 — OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITH CC[MS-DRG]: “OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITH CC — Other Ear, Nose, Mouth and Throat O.R. Procedures (MDC 03)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 145 — OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITHOUT CC/MCC[MS-DRG]: “OTHER EAR, NOSE, MOUTH AND THROAT O.R. PROCEDURES WITHOUT CC/MCC — Other Ear, Nose, Mouth and Throat O.R. Procedures (MDC 03)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 252 — OTHER VASCULAR PROCEDURES WITH MCC[MS-DRG]: “OTHER VASCULAR PROCEDURES WITH MCC — Other Vascular Procedures (MDC 05)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- DRG 253 — OTHER VASCULAR PROCEDURES WITH CC[MS-DRG]: “OTHER VASCULAR PROCEDURES WITH CC — Other Vascular Procedures (MDC 05)”— CMS MS-DRG Definitions Manual (Appendix E) · FY2026
- and 10 more
Clinical classification (CCSR)
- CAR029 — Cardiovascular device procedures, NEC[CCSR category]: “Cardiovascular device procedures, NEC — Cardiovascular Procedures”— AHRQ CCSR for ICD-10-PCS Procedures (HCUP) · v2026.1
MDC crossing · diagnoses (5924)
- MDC 01 — Diseases and Disorders of the Nervous System[MDC crossing]: “Diseases and Disorders of the Nervous System — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”— CMS MS-DRG Definitions Manual · FY2026
- MDC 03 — Diseases and Disorders of the Ear, Nose, Mouth and Throat[MDC crossing]: “Diseases and Disorders of the Ear, Nose, Mouth and Throat — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”— CMS MS-DRG Definitions Manual · FY2026
- A02.21 — Salmonella meningitis[Same-MDC diagnosis]: “Salmonella meningitis — grouped in MDC 01, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A06.6 — Amebic brain abscess[Same-MDC diagnosis]: “Amebic brain abscess — grouped in MDC 01, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A17.0 — Tuberculous meningitis[Same-MDC diagnosis]: “Tuberculous meningitis — grouped in MDC 01, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A17.1 — Meningeal tuberculoma[Same-MDC diagnosis]: “Meningeal tuberculoma — grouped in MDC 01, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- A17.81 — Tuberculoma of brain and spinal cord[Same-MDC diagnosis]: “Tuberculoma of brain and spinal cord — grouped in MDC 01, the diagnosis side of this code's crossing.”— CMS MS-DRG Definitions Manual (Appendix B) · FY2026
- and 5919 more
Nearest codes
- 05HY02Z — Insertion of Monitoring Device into Upper Vein, Open Approach[One axis away]— CMS ICD-10-PCS tables
- 05HY03Z — Insertion of Infusion Device into Upper Vein, Open Approach[One axis away]— CMS ICD-10-PCS tables
- 05HY0DZ — Insertion of Intraluminal Device into Upper Vein, Open Approach[One axis away]— CMS ICD-10-PCS tables
- 05HY3YZ — Insertion of Other Device into Upper Vein, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 05HY4YZ — Insertion of Other Device into Upper Vein, Percutaneous Endoscopic Approach[One axis away]— CMS ICD-10-PCS tables
Change history
No changes recorded for this code. This ledger tracks additions, deletions and description changes from FY2026 (April) onward. Note changes are not tracked.
Read from: CMS ICD-10-PCS code tables, index and definitions — FY2026 (April); CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v43; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels