Skip to main content
Inpatient Procedure Code

06WYXJZ ICD-10-PCS Code: Revision of Synthetic Substitute in Lower Vein, External Approach

Revision of Synth Sub in Low Vein, Extern Approach

Axis Breakdown

Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.

PositionValueMeaning
1
Section0

Medical and Surgical

2
Body System6

Lower Veins

3
Root OperationW

Revision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

4
Body PartY

Lower Vein

5
ApproachX

External

6
DeviceJ

Synthetic Substitute

7
QualifierZ

No Qualifier

Related Codes

Same operation — other Approach

Same table and root operation, differing only in the approach character.

06WY0JZ — Revision of Synthetic Substitute in Lower Vein, Open Approach, 06WY3JZ — Revision of Synthetic Substitute in Lower Vein, Percutaneous Approach, 06WY4JZ — Revision of Synthetic Substitute in Lower Vein, Percutaneous Endoscopic Approach

Same operation — other Device

Same table and root operation, differing only in the device character.

06WYX0Z — Revision of Drainage Device in Lower Vein, External Approach, 06WYX2Z — Revision of Monitoring Device in Lower Vein, External Approach, 06WYX3Z — Revision of Infusion Device in Lower Vein, External Approach, 06WYX7Z — Revision of Autologous Tissue Substitute in Lower Vein, External Approach, 06WYXCZ — Revision of Extraluminal Device in Lower Vein, External Approach, 06WYXDZ — Revision of Intraluminal Device in Lower Vein, External Approach, 06WYXKZ — Revision of Nonautologous Tissue Substitute in Lower Vein, External Approach

Same procedure category (CCSR), other tables

AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Cardiovascular device procedures, NEC (Cardiovascular Procedures); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.

06PY3JZ — Removal of Synthetic Substitute from Lower Vein, Percutaneous Approach, 06PY3KZ — Removal of Nonautologous Tissue Substitute from Lower Vein, Percutaneous Approach, 06PY3YZ — Removal of Other Device from Lower Vein, Percutaneous Approach, 06PY43Z — Removal of Infusion Device from Lower Vein, Percutaneous Endoscopic Approach, 06PY47Z — Removal of Autologous Tissue Substitute from Lower Vein, Percutaneous Endoscopic Approach, 06PY4CZ — Removal of Extraluminal Device from Lower Vein, Percutaneous Endoscopic Approach, 06PY4JZ — Removal of Synthetic Substitute from Lower Vein, Percutaneous Endoscopic Approach, 06PY4KZ — Removal of Nonautologous Tissue Substitute from Lower Vein, Percutaneous Endoscopic Approach, 06PY4YZ — Removal of Other Device from Lower Vein, Percutaneous Endoscopic Approach, 06PYX3Z — Removal of Infusion Device from Lower Vein, External Approach, X2H03R9 — Insertion of Intraluminal Device, Bioprosthetic Valve into Inferior Vena Cava, Percutaneous Approach, New Technology Group 9, X2H13R9 — Insertion of Intraluminal Device, Bioprosthetic Valve into Superior Vena Cava, Percutaneous Approach, New Technology Group 9, X2H20R9 — Insertion of Intraluminal Device, Bioprosthetic Valve into Right Femoral Vein, Open Approach, New Technology Group 9, X2H30R9 — Insertion of Intraluminal Device, Bioprosthetic Valve into Left Femoral Vein, Open Approach, New Technology Group 9, X2HP38B — Insertion of Temporary Intraluminal Device into Right Anterior Tibial Artery, Percutaneous Approach, New Technology Group 11, X2HQ38B — Insertion of Temporary Intraluminal Device into Left Anterior Tibial Artery, Percutaneous Approach, New Technology Group 11, X2HR38B — Insertion of Temporary Intraluminal Device into Right Posterior Tibial Artery, Percutaneous Approach, New Technology Group 11, X2HS38B — Insertion of Temporary Intraluminal Device into Left Posterior Tibial Artery, Percutaneous Approach, New Technology Group 11, X2HT38B — Insertion of Temporary Intraluminal Device into Right Peroneal Artery, Percutaneous Approach, New Technology Group 11, X2HU38B — Insertion of Temporary Intraluminal Device into Left Peroneal Artery, Percutaneous Approach, New Technology Group 11, +569 more

Contextual Map

Every relationship of 06WYXJZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.

PCS table

Clinical classification (CCSR)

Nearest codes

Change history

No changes recorded for this code. This ledger tracks additions, deletions and description changes from FY2026 (April) onward. Note changes are not tracked.

Read from: CMS ICD-10-PCS code tables, index and definitions — FY2026 (April); CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v43; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels