0TP582Z ICD-10-PCS Code: Removal of Monitoring Device from Kidney, Via Natural or Artificial Opening Endoscopic
Removal of Monitoring Device from Kidney, Endo
Axis Breakdown
Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.
| Position | Value | Meaning |
|---|---|---|
| 1 | Section0 | Medical and Surgical |
| 2 | Body SystemT | Urinary System |
| 3 | Root OperationP | Removal Taking out or off a device from a body part |
| 4 | Body Part5 | Kidney |
| 5 | Approach8 | Via Natural or Artificial Opening Endoscopic |
| 6 | Device2 | Monitoring Device |
| 7 | QualifierZ | No Qualifier |
Related Codes
Same operation — other Body Part
Same table and root operation, differing only in the body part character.
0TP982Z — Removal of Monitoring Device from Ureter, Via Natural or Artificial Opening Endoscopic, 0TPB82Z — Removal of Monitoring Device from Bladder, Via Natural or Artificial Opening Endoscopic, 0TPD82Z — Removal of Monitoring Device from Urethra, Via Natural or Artificial Opening Endoscopic
Same operation — other Approach
Same table and root operation, differing only in the approach character.
0TP502Z — Removal of Monitoring Device from Kidney, Open Approach, 0TP532Z — Removal of Monitoring Device from Kidney, Percutaneous Approach, 0TP542Z — Removal of Monitoring Device from Kidney, Percutaneous Endoscopic Approach, 0TP572Z — Removal of Monitoring Device from Kidney, Via Natural or Artificial Opening, 0TP5X2Z — Removal of Monitoring Device from Kidney, External Approach
Same operation — other Device
Same table and root operation, differing only in the device character.
0TP580Z — Removal of Drainage Device from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP583Z — Removal of Infusion Device from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP587Z — Removal of Autologous Tissue Substitute from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP58CZ — Removal of Extraluminal Device from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP58DZ — Removal of Intraluminal Device from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP58JZ — Removal of Synthetic Substitute from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP58KZ — Removal of Nonautologous Tissue Substitute from Kidney, Via Natural or Artificial Opening Endoscopic, 0TP58YZ — Removal of Other Device from Kidney, Via Natural or Artificial Opening Endoscopic
Same procedure category (CCSR), other tables
AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Urinary system procedures, NEC (Urinary System Procedures); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.
0TNC3ZZ — Release Bladder Neck, Percutaneous Approach, 0TNC4ZZ — Release Bladder Neck, Percutaneous Endoscopic Approach, 0TNC7ZZ — Release Bladder Neck, Via Natural or Artificial Opening, 0TNC8ZZ — Release Bladder Neck, Via Natural or Artificial Opening Endoscopic, 0TND0ZZ — Release Urethra, Open Approach, 0TND3ZZ — Release Urethra, Percutaneous Approach, 0TND4ZZ — Release Urethra, Percutaneous Endoscopic Approach, 0TND7ZZ — Release Urethra, Via Natural or Artificial Opening, 0TND8ZZ — Release Urethra, Via Natural or Artificial Opening Endoscopic, 0TNDXZZ — Release Urethra, External Approach, 0TR307Z — Replacement of Right Kidney Pelvis with Autologous Tissue Substitute, Open Approach, 0TR30JZ — Replacement of Right Kidney Pelvis with Synthetic Substitute, Open Approach, 0TR30KZ — Replacement of Right Kidney Pelvis with Nonautologous Tissue Substitute, Open Approach, 0TR347Z — Replacement of Right Kidney Pelvis with Autologous Tissue Substitute, Percutaneous Endoscopic Approach, 0TR34JZ — Replacement of Right Kidney Pelvis with Synthetic Substitute, Percutaneous Endoscopic Approach, 0TR34KZ — Replacement of Right Kidney Pelvis with Nonautologous Tissue Substitute, Percutaneous Endoscopic Approach, 0TR377Z — Replacement of Right Kidney Pelvis with Autologous Tissue Substitute, Via Natural or Artificial Opening, 0TR37JZ — Replacement of Right Kidney Pelvis with Synthetic Substitute, Via Natural or Artificial Opening, 0TR37KZ — Replacement of Right Kidney Pelvis with Nonautologous Tissue Substitute, Via Natural or Artificial Opening, 0TR387Z — Replacement of Right Kidney Pelvis with Autologous Tissue Substitute, Via Natural or Artificial Opening Endoscopic, +629 more
Contextual Map
Every relationship of 0TP582Z in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
PCS table
- 0TP[PCS table]— CMS ICD-10-PCS tables
- Medical and Surgical — Section: Medical and Surgical[Section]: “Medical and Surgical”— CMS ICD-10-PCS tables
- Urinary System — Body System: Urinary System[Body System]: “Urinary System”— CMS ICD-10-PCS tables
- Removal — Operation: Removal[Operation]: “Removal”— CMS ICD-10-PCS tables
Clinical classification (CCSR)
- URN012 — Urinary system procedures, NEC[CCSR category]: “Urinary system procedures, NEC — Urinary System Procedures”— AHRQ CCSR for ICD-10-PCS Procedures (HCUP) · v2026.1
Nearest codes
- 0TP502Z — Removal of Monitoring Device from Kidney, Open Approach[One axis away]— CMS ICD-10-PCS tables
- 0TP532Z — Removal of Monitoring Device from Kidney, Percutaneous Approach[One axis away]— CMS ICD-10-PCS tables
- 0TP542Z — Removal of Monitoring Device from Kidney, Percutaneous Endoscopic Approach[One axis away]— CMS ICD-10-PCS tables
- 0TP572Z — Removal of Monitoring Device from Kidney, Via Natural or Artificial Opening[One axis away]— CMS ICD-10-PCS tables
- 0TP580Z — Removal of Drainage Device from Kidney, Via Natural or Artificial Opening Endoscopic[One axis away]— CMS ICD-10-PCS tables
- 0TP583Z — Removal of Infusion Device from Kidney, Via Natural or Artificial Opening Endoscopic[One axis away]— CMS ICD-10-PCS tables
- 0TP587Z — Removal of Autologous Tissue Substitute from Kidney, Via Natural or Artificial Opening Endoscopic[One axis away]— CMS ICD-10-PCS tables
- 0TP58CZ — Removal of Extraluminal Device from Kidney, Via Natural or Artificial Opening Endoscopic[One axis away]— CMS ICD-10-PCS tables
Change history
No changes recorded for this code. This ledger tracks additions, deletions and description changes from FY2016 onward. Note changes are not tracked.
Read from: CMS ICD-10-PCS code tables, index and definitions — FY2027; CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v44; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels · How MedCoder verifies its implementation
Current data releases:ICD-10-CM FY2027 · ICD-10-PCS FY2027 · HCPCS October 2026 · MS-DRG v44 · Medicare Code Editor v44.0 · NCCI PTP Q4 2026 · MUE Q4 2026 · NCD code lists 2026-01 · LCD export September 28, 2026 · All releases and sources