0WP10YZ
Removal of Other Device from Cranial Cavity, Open Approach
Axis Breakdown
Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.
| Position | Value | Meaning |
|---|---|---|
| 1 | Section0 | Medical and Surgical |
| 2 | Body SystemW | Anatomical Regions, General |
| 3 | Root OperationP | Removal Taking out or off a device from a body part |
| 4 | Body Part1 | Cranial Cavity |
| 5 | Approach0 | Open |
| 6 | DeviceY | Other Device |
| 7 | QualifierZ | No Qualifier |
Potential MS-DRG Relationships (FY2026)
The MS-DRG grouper treats this as an operating room procedure. It appears in the surgical logic of 5 MS-DRGs:
- MDC 01 — Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis: DRG 023, DRG 024
- MDC 01 — Craniotomy and endovascular intracranial procedures: DRG 025, DRG 026, DRG 027
From the CMS MS-DRG Definitions Manual, Appendix E. Actual DRG assignment depends on the complete claim.
Contextual Map
Every relationship of 0WP10YZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
PCS table
- 0WP[PCS table]
- [object Object] — Section: [object Object] [Section]: “[object Object]”
- [object Object] — Body System: [object Object] [Body System]: “[object Object]”
- [object Object] — Operation: [object Object] [Operation]: “[object Object]”
MS-DRG participation
- DRG 023 — CRANIOTOMY WITH MAJOR DEVICE IMPLANT OR ACUTE COMPLEX CNS PRINCIPAL DIAGNOSIS WITH MCC OR ANTINEOPLASTIC IMPLANT OR EPILEPSY WITH NEUROSTIMULATOR [MS-DRG]: “CRANIOTOMY WITH MAJOR DEVICE IMPLANT OR ACUTE COMPLEX CNS PRINCIPAL DIAGNOSIS WITH MCC OR ANTINEOPLASTIC IMPLANT OR EPILEPSY WITH NEUROSTIMULATOR — Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis (MDC 01)”
- DRG 024 — CRANIOTOMY WITH MAJOR DEVICE IMPLANT OR ACUTE COMPLEX CNS PRINCIPAL DIAGNOSIS WITHOUT MCC [MS-DRG]: “CRANIOTOMY WITH MAJOR DEVICE IMPLANT OR ACUTE COMPLEX CNS PRINCIPAL DIAGNOSIS WITHOUT MCC — Craniotomy with Major Device Implant or Acute Complex CNS Principal Diagnosis (MDC 01)”
- DRG 025 — CRANIOTOMY AND ENDOVASCULAR INTRACRANIAL PROCEDURES WITH MCC [MS-DRG]: “CRANIOTOMY AND ENDOVASCULAR INTRACRANIAL PROCEDURES WITH MCC — Craniotomy and endovascular intracranial procedures (MDC 01)”
- DRG 026 — CRANIOTOMY AND ENDOVASCULAR INTRACRANIAL PROCEDURES WITH CC [MS-DRG]: “CRANIOTOMY AND ENDOVASCULAR INTRACRANIAL PROCEDURES WITH CC — Craniotomy and endovascular intracranial procedures (MDC 01)”
- DRG 027 — CRANIOTOMY AND ENDOVASCULAR INTRACRANIAL PROCEDURES WITHOUT CC/MCC [MS-DRG]: “CRANIOTOMY AND ENDOVASCULAR INTRACRANIAL PROCEDURES WITHOUT CC/MCC — Craniotomy and endovascular intracranial procedures (MDC 01)”
MDC crossing · diagnoses (2636)
- MDC 01 — Diseases and Disorders of the Nervous System [MDC crossing]: “Diseases and Disorders of the Nervous System — the grouper's crossing between diagnoses and procedures: a principal diagnosis sets the MDC, and same-MDC procedures move the stay to its surgical DRGs.”
- A02.21 — Salmonella meningitis [Same-MDC diagnosis]: “Salmonella meningitis — grouped in MDC 01, the diagnosis side of this code's crossing.”
- A06.6 — Amebic brain abscess [Same-MDC diagnosis]: “Amebic brain abscess — grouped in MDC 01, the diagnosis side of this code's crossing.”
- A17.0 — Tuberculous meningitis [Same-MDC diagnosis]: “Tuberculous meningitis — grouped in MDC 01, the diagnosis side of this code's crossing.”
- A17.1 — Meningeal tuberculoma [Same-MDC diagnosis]: “Meningeal tuberculoma — grouped in MDC 01, the diagnosis side of this code's crossing.”
- A17.81 — Tuberculoma of brain and spinal cord [Same-MDC diagnosis]: “Tuberculoma of brain and spinal cord — grouped in MDC 01, the diagnosis side of this code's crossing.”
- and 2631 more
Nearest codes
- 0WP00YZ — Removal of Other Device from Head, Open Approach [One axis away]
- 0WP100Z — Removal of Drainage Device from Cranial Cavity, Open Approach [One axis away]
- 0WP101Z — Removal of Radioactive Element from Cranial Cavity, Open Approach [One axis away]
- 0WP103Z — Removal of Infusion Device from Cranial Cavity, Open Approach [One axis away]
- 0WP10JZ — Removal of Synthetic Substitute from Cranial Cavity, Open Approach [One axis away]
- 0WP13YZ — Removal of Other Device from Cranial Cavity, Percutaneous Approach [One axis away]
- 0WP14YZ — Removal of Other Device from Cranial Cavity, Percutaneous Endoscopic Approach [One axis away]
- 0WP20YZ — Removal of Other Device from Face, Open Approach [One axis away]
Change history
No changes recorded for this code — unchanged since the FY2026 (April) baseline of the change ledger.