Skip to main content
Inpatient Procedure Code

0WWCXGZ ICD-10-PCS Code: Revision of Defibrillator Lead in Mediastinum, External Approach

Revision of Defib Lead in Mediastinum, Extern Approach

Axis Breakdown

Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.

PositionValueMeaning
1
Section0

Medical and Surgical

2
Body SystemW

Anatomical Regions, General

3
Root OperationW

Revision

Correcting, to the extent possible, a portion of a malfunctioning device or the position of a displaced device

4
Body PartC

Mediastinum

5
ApproachX

External

6
DeviceG

Defibrillator Lead

7
QualifierZ

No Qualifier

Related Codes

Same operation — other Approach

Same table and root operation, differing only in the approach character.

0WWC0GZ — Revision of Defibrillator Lead in Mediastinum, Open Approach, 0WWC3GZ — Revision of Defibrillator Lead in Mediastinum, Percutaneous Approach, 0WWC4GZ — Revision of Defibrillator Lead in Mediastinum, Percutaneous Endoscopic Approach

Same operation — other Device

Same table and root operation, differing only in the device character.

0WWCX0Z — Revision of Drainage Device in Mediastinum, External Approach, 0WWCX1Z — Revision of Radioactive Element in Mediastinum, External Approach, 0WWCX3Z — Revision of Infusion Device in Mediastinum, External Approach, 0WWCX7Z — Revision of Autologous Tissue Substitute in Mediastinum, External Approach, 0WWCXJZ — Revision of Synthetic Substitute in Mediastinum, External Approach, 0WWCXKZ — Revision of Nonautologous Tissue Substitute in Mediastinum, External Approach, 0WWCXYZ — Revision of Other Device in Mediastinum, External Approach

Same procedure category (CCSR), other tables

AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Pacemaker and defibrillator procedures (Cardiovascular Procedures); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.

0JPT0PZ — Removal of Cardiac Rhythm Related Device from Trunk Subcutaneous Tissue and Fascia, Open Approach, 0JPT3FZ — Removal of Subcutaneous Defibrillator Lead from Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach, 0JPT3PZ — Removal of Cardiac Rhythm Related Device from Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach, 0JWT0FZ — Revision of Subcutaneous Defibrillator Lead in Trunk Subcutaneous Tissue and Fascia, Open Approach, 0JWT0PZ — Revision of Cardiac Rhythm Related Device in Trunk Subcutaneous Tissue and Fascia, Open Approach, 0JWT3FZ — Revision of Subcutaneous Defibrillator Lead in Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach, 0JWT3PZ — Revision of Cardiac Rhythm Related Device in Trunk Subcutaneous Tissue and Fascia, Percutaneous Approach, 0JWTXFZ — Revision of Subcutaneous Defibrillator Lead in Trunk Subcutaneous Tissue and Fascia, External Approach, 0JWTXPZ — Revision of Cardiac Rhythm Related Device in Trunk Subcutaneous Tissue and Fascia, External Approach, 0WHC0GZ — Insertion of Defibrillator Lead into Mediastinum, Open Approach, 0WHC3GZ — Insertion of Defibrillator Lead into Mediastinum, Percutaneous Approach, 0WHC4GZ — Insertion of Defibrillator Lead into Mediastinum, Percutaneous Endoscopic Approach, 0WPC0GZ — Removal of Defibrillator Lead from Mediastinum, Open Approach, 0WPC3GZ — Removal of Defibrillator Lead from Mediastinum, Percutaneous Approach, 0WPC4GZ — Removal of Defibrillator Lead from Mediastinum, Percutaneous Endoscopic Approach, 0WPCXGZ — Removal of Defibrillator Lead from Mediastinum, External Approach, X2H63V9 — Insertion of Dual-Chamber Intracardiac Pacemaker into Right Atrium, Percutaneous Approach, New Technology Group 9, X2HK3V9 — Insertion of Dual-Chamber Intracardiac Pacemaker into Right Ventricle, Percutaneous Approach, New Technology Group 9, X2HN37B — Insertion of Endocardiac Pacing Electrode into Left Ventricle, Percutaneous Approach, New Technology Group 11, XHH80HB — Insertion of Ultrasound Transmitter and Battery for Endocardiac Pacing Electrode into Chest Subcutaneous Tissue and Fascia, Open Approach, New Technology Group 11, +119 more

Contextual Map

Every relationship of 0WWCXGZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.

PCS table

Clinical classification (CCSR)

Nearest codes

Change history

No changes recorded for this code. This ledger tracks additions, deletions and description changes from FY2026 (April) onward. Note changes are not tracked.

Read from: CMS ICD-10-PCS code tables, index and definitions — FY2026 (April); CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v43; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels