Skip to main content
Inpatient Procedure Code

0VN00ZZ ICD-10-PCS Code: Release Prostate, Open Approach

Check this code on a claim

Axis Breakdown

Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.

PositionValueMeaning
1
Section0

Medical and Surgical

2
Body SystemV

Male Reproductive System

3
Root OperationN

Release

Freeing a body part from an abnormal physical constraint by cutting or by the use of force

4
Body Part0

Prostate

5
Approach0

Open

6
DeviceZ

No Device

7
QualifierZ

No Qualifier

MS-DRG Grouper Relationships (FY2027)

Potential MS-DRG participation — not a DRG assignment.

The MS-DRG grouper treats this as an operating room procedure. It appears in the surgical logic of 10 MS-DRGs:

From the CMS MS-DRG Definitions Manual, Appendix E. Actual DRG assignment depends on the complete claim.

Related Codes

Same operation — other Body Part

Same table and root operation, differing only in the body part character.

0VN10ZZ — Release Right Seminal Vesicle, Open Approach, 0VN20ZZ — Release Left Seminal Vesicle, Open Approach, 0VN30ZZ — Release Bilateral Seminal Vesicles, Open Approach, 0VN50ZZ — Release Scrotum, Open Approach, 0VN60ZZ — Release Right Tunica Vaginalis, Open Approach, 0VN70ZZ — Release Left Tunica Vaginalis, Open Approach, 0VN90ZZ — Release Right Testis, Open Approach, 0VNB0ZZ — Release Left Testis, Open Approach, +12 more

Same operation — other Approach

Same table and root operation, differing only in the approach character.

0VN03ZZ — Release Prostate, Percutaneous Approach, 0VN04ZZ — Release Prostate, Percutaneous Endoscopic Approach, 0VN07ZZ — Release Prostate, Via Natural or Artificial Opening, 0VN08ZZ — Release Prostate, Via Natural or Artificial Opening Endoscopic

Same procedure category (CCSR), other tables

AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Prostate and seminal vesicle procedures (excluding prostatectomy) (Male Reproductive System Procedures); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.

0VH443Z — Insertion of Infusion Device into Prostate and Seminal Vesicles, Percutaneous Endoscopic Approach, 0VH44YZ — Insertion of Other Device into Prostate and Seminal Vesicles, Percutaneous Endoscopic Approach, 0VH473Z — Insertion of Infusion Device into Prostate and Seminal Vesicles, Via Natural or Artificial Opening, 0VH47YZ — Insertion of Other Device into Prostate and Seminal Vesicles, Via Natural or Artificial Opening, 0VH483Z — Insertion of Infusion Device into Prostate and Seminal Vesicles, Via Natural or Artificial Opening Endoscopic, 0VH48YZ — Insertion of Other Device into Prostate and Seminal Vesicles, Via Natural or Artificial Opening Endoscopic, 0VJ40ZZ — Inspection of Prostate and Seminal Vesicles, Open Approach, 0VJ43ZZ — Inspection of Prostate and Seminal Vesicles, Percutaneous Approach, 0VJ44ZZ — Inspection of Prostate and Seminal Vesicles, Percutaneous Endoscopic Approach, 0VJ4XZZ — Inspection of Prostate and Seminal Vesicles, External Approach, 0VP400Z — Removal of Drainage Device from Prostate and Seminal Vesicles, Open Approach, 0VP403Z — Removal of Infusion Device from Prostate and Seminal Vesicles, Open Approach, 0VP407Z — Removal of Autologous Tissue Substitute from Prostate and Seminal Vesicles, Open Approach, 0VP40JZ — Removal of Synthetic Substitute from Prostate and Seminal Vesicles, Open Approach, 0VP40KZ — Removal of Nonautologous Tissue Substitute from Prostate and Seminal Vesicles, Open Approach, 0VP40YZ — Removal of Other Device from Prostate and Seminal Vesicles, Open Approach, 0VP430Z — Removal of Drainage Device from Prostate and Seminal Vesicles, Percutaneous Approach, 0VP433Z — Removal of Infusion Device from Prostate and Seminal Vesicles, Percutaneous Approach, 0VP437Z — Removal of Autologous Tissue Substitute from Prostate and Seminal Vesicles, Percutaneous Approach, 0VP43JZ — Removal of Synthetic Substitute from Prostate and Seminal Vesicles, Percutaneous Approach, +213 more

Contextual Map

Every relationship of 0VN00ZZ in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.

Run 0VN00ZZ with these 5 related codes in Claim Check

PCS table

MS-DRG participation (10)

Clinical classification (CCSR)

MDC crossing · diagnoses (15515)

Nearest codes

Change history

No changes recorded for this code. This ledger tracks additions, deletions and description changes from FY2016 onward. Note changes are not tracked.

Read from: CMS ICD-10-PCS code tables, index and definitions — FY2027; CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v44; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels · How MedCoder verifies its implementation

Current data releases:ICD-10-CM FY2027 · ICD-10-PCS FY2027 · HCPCS October 2026 · MS-DRG v44 · Medicare Code Editor v44.0 · NCCI PTP Q4 2026 · MUE Q4 2026 · NCD code lists 2026-01 · LCD export September 28, 2026 · All releases and sources