D717B6Z ICD-10-PCS Code: Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Cesium 131 (Cs-131)
LDR Brachytherapy of Pelvis Lymph using Cesium 131
Axis Breakdown
Every ICD-10-PCS code is exactly seven characters, one per axis. Each character's meaning is defined by its position in the code.
| Position | Value | Meaning |
|---|---|---|
| 1 | SectionD | Radiation Therapy |
| 2 | Body System7 | Lymphatic and Hematologic System |
| 3 | Modality1 | Brachytherapy |
| 4 | Treatment Site7 | Lymphatics, Pelvis |
| 5 | Modality QualifierB | Low Dose Rate (LDR) |
| 6 | Isotope6 | Cesium 131 (Cs-131) |
| 7 | QualifierZ | None |
Related Codes
Same operation — other Treatment Site
Same table and root operation, differing only in the treatment site character.
D710B6Z — Low Dose Rate (LDR) Brachytherapy of Bone Marrow using Cesium 131 (Cs-131), D711B6Z — Low Dose Rate (LDR) Brachytherapy of Thymus using Cesium 131 (Cs-131), D712B6Z — Low Dose Rate (LDR) Brachytherapy of Spleen using Cesium 131 (Cs-131), D713B6Z — Low Dose Rate (LDR) Brachytherapy of Neck Lymphatics using Cesium 131 (Cs-131), D714B6Z — Low Dose Rate (LDR) Brachytherapy of Axillary Lymphatics using Cesium 131 (Cs-131), D715B6Z — Low Dose Rate (LDR) Brachytherapy of Thorax Lymphatics using Cesium 131 (Cs-131), D716B6Z — Low Dose Rate (LDR) Brachytherapy of Abdomen Lymphatics using Cesium 131 (Cs-131), D718B6Z — Low Dose Rate (LDR) Brachytherapy of Inguinal Lymphatics using Cesium 131 (Cs-131)
Same operation — other Isotope
Same table and root operation, differing only in the isotope character.
D717B7Z — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Cesium 137 (Cs-137), D717B8Z — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Iridium 192 (Ir-192), D717B9Z — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Iodine 125 (I-125), D717BBZ — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Palladium 103 (Pd-103), D717BCZ — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Californium 252 (Cf-252), D717BYZ — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Other Isotope
Same procedure category (CCSR), other tables
AHRQ's Clinical Classifications Software Refined groups these ICD-10-PCS procedures with this one under Brachytherapy (Radiation Therapy); listed here are the members in other PCS tables. Source: Clinical Classifications Software Refined (CCSR), Healthcare Cost and Utilization Project (HCUP), Agency for Healthcare Research and Quality, November 2025.
+1578 more
Contextual Map
Every relationship of D717B6Z in one view: hierarchy, official tabular instructions in both directions, clinical classification, risk adjustment, MS-DRG participation, index terms and change history — each edge carrying the CMS source it derives from.
PCS table
- D71[PCS table]— CMS ICD-10-PCS tables
- Radiation Therapy — Section: Radiation Therapy[Section]: “Radiation Therapy”— CMS ICD-10-PCS tables
- Lymphatic and Hematologic System — Body System: Lymphatic and Hematologic System[Body System]: “Lymphatic and Hematologic System”— CMS ICD-10-PCS tables
- Brachytherapy — Operation: Brachytherapy[Operation]: “Brachytherapy”— CMS ICD-10-PCS tables
Clinical classification (CCSR)
- RAD002 — Brachytherapy[CCSR category]: “Brachytherapy — Radiation Therapy”— AHRQ CCSR for ICD-10-PCS Procedures (HCUP) · v2026.1
Nearest codes
- D710B6Z — Low Dose Rate (LDR) Brachytherapy of Bone Marrow using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D711B6Z — Low Dose Rate (LDR) Brachytherapy of Thymus using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D712B6Z — Low Dose Rate (LDR) Brachytherapy of Spleen using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D713B6Z — Low Dose Rate (LDR) Brachytherapy of Neck Lymphatics using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D714B6Z — Low Dose Rate (LDR) Brachytherapy of Axillary Lymphatics using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D715B6Z — Low Dose Rate (LDR) Brachytherapy of Thorax Lymphatics using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D716B6Z — Low Dose Rate (LDR) Brachytherapy of Abdomen Lymphatics using Cesium 131 (Cs-131)[One axis away]— CMS ICD-10-PCS tables
- D717B7Z — Low Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Cesium 137 (Cs-137)[One axis away]— CMS ICD-10-PCS tables
Change history
- FY2021 — Added to the code set[Change history]— CMS release files (code change ledger) · icd10pcs-fy2021
Change history
- FY2021 — October 1, 2020Added to the code setLow Dose Rate (LDR) Brachytherapy of Pelvis Lymphatics using Cesium 131 (Cs-131)FY2021 changes
Read from: CMS ICD-10-PCS code tables, index and definitions — FY2027; CMS MS-DRG Definitions Manual (incl. Appendix B diagnosis index, Appendix C CC/MCC list, Appendix E procedure index) and IPPS Final Rule tables — v44; AHRQ HCUP Clinical Classifications Software Refined for ICD-10-PCS Procedures (hcup-us.ahrq.gov/toolssoftware/ccsr/PRCCSR_v2026-1.zip) — v2026.1. All data sources · How to read the labels · How MedCoder verifies its implementation
Current data releases:ICD-10-CM FY2027 · ICD-10-PCS FY2027 · HCPCS October 2026 · MS-DRG v44 · Medicare Code Editor v44.0 · NCCI PTP Q4 2026 · MUE Q4 2026 · NCD code lists 2026-01 · LCD export September 28, 2026 · All releases and sources